High Flame Retardant Thermoplastic Low Smoke Halogen-Free Polyolefin Cable Material

High Flame Retardant Thermoplastic Low Smoke Halogen-Free Polyolefin Cable Material

Product Name, Model Type and Usage


Product Model

Product Name

Characteristics and uses

SH8512

High Flame Retardant Thermoplastic Low Smoke Halogen-Free Polyolefin Cable Material

High flame retardant requirements for power cables, control cables, boats and indoor and outdoor optical cables.


Product introduction

SH8512 is a thermoplastic low smoke halogen-free flame retardant polyolefin cable material with excellent flame retardant and cracking resistance. It is mainly used in power cables, control cables, signal cables, marine cables, indoor and outdoor optical cables, integrated cabling and so on.

SH8512 meets the requirements of JB/T 10707-2007, YD/T 1113-2001, GB/T 1966-2005, IEC 60092, SHFI and other product standards. It also meets the requirements of RoHS and REACH. It is a green and environmental resistant fuel.

Product characteristics

·Excellent Cracking Resistance                 ·Low smoke emission and low corrosivity

·Excellent resistance to high and low temperature              ·Good extrusion performance

·Higher flame retardancy

Processing Guidelines

The best extrusion effect can be obtained by using 1:1.2 low compression ratio screw. PE/PVC screw extrusion can also be used.

Recommended processing temperature:

position 1area 2area 3area 4area 5area nose die port
temperature(℃) 120 145 155 165 165 167 160-167

The melt temperature should be controlled between 160 and 175 degrees C, and the maximum should not exceed 180 degrees C.

If the material is stored in humid environment for a long time, drying treatment is recommended. The drying temperature is 80 C and the drying time is 1-2 hours.

Storage and Packaging

It should be stored in a dry and ventilated warehouse.

The products are packed in 25kg paper-plastic composite bags or 500kg container bags. It can also be packed according to user's requirements.

Technical characteristics

physical property

unit

SH8512 typical value

test method

density

g/cm3

1.5

GB/T 1033.1

low temperature embrittlement temperature(-40℃)number of failures

0

GB/T 5470

thermal deformation(90℃×4h)

%

4

GB/T 8815

high temperature and high pressure(90℃)

%

30

GB/T 2951.31

 

 

 

 

mechanical properties

unit

SH8512 typical value

test method

tensile strength

MPa

14.3

GB/T 1040

elongation at break

%

215

GB/T 1040

thermal aging properties110℃×7天

 

 

GB/T 2951.12

tensile strength change rate

%

+8

 

max change of elongation at break

%

-5

 

 

 

 

 

electrical performance

unit

SH8512 typical value

test method

20℃ volumetric resistivity

Ω·m

8.7×1011

GB/T 1410

dielectric strength

MV/m

27

GB/T 1408.1

 

 

 

 

combustion performance

unit

SH8512 typical value

test method

oxygen index

%

38

GB/T 2406

acid gas

 

 

GB/T 17650.2

conductivity

us/mm

0.96

 

PH value

 

5.7

 

maximum smoke density Dm

 

 

ASTME662

smoking method

-

48

 

smoke-free method

-

191

 

toxicity index

-

1.1

NES713